Kewtech KT66EV Multifunction Tester & EVSE Adaptor Kit

Kewtech KT66EV Multifunction Tester & EVSE Adaptor Kit Reviews

A product’s star rating is calculated as the average of all its reviews.


Test Meter Group Ltd logo

Sold by Test Meter Group Ltd

www.test-meter.co.uk

6.3K Reviews

4.7

The information on this page is based solely on product reviews written by customers of Test Meter Group Ltd via Trustpilot.


Here’s what people highlighted

Quality

5.0

1 rating

Value for money

5.0

1 rating


Product details

Brand: Kewtech

{{widget type="Magento\Cms\Block\Widget\Block" template="widget/static_block/default.phtml" block_id="161" type_name="CMS Static Block"}}{{widget type="Magento\Cms\Block\Widget\Block" template="widget/static_block/default.phtml" block_id="237" type_name="CMS Static Block"}}Kewtech KT66EV Multifunction Tester & EVSE Adaptor Kit The Kewtech KT66EV Multifunction Tester & EVSE Adaptor Kit is the ultimate package for installation testing, especially for those which involve electric vehicle charging points. Test electrical safety alongside EVSE functionality, including any EV points installed with Type B RCDs or with 6mA residual direct current devices, and in either TN or TT configurations. Kewtech KT66DL 12-in-1 Multifunction Tester The Kewtech KT66DL 12-in-1 Multifunction Tester provides a comprehensive suite of features, such as a pioneering loop testing system which includes both 2 & 3 wire low current test options. Anti-Trip technology (ATT) for no trip LOOP L-PE testing on all RCDs is incorporated as is an in-depth RCD testing facility. Built for domestic, commercial and industrial installations, the KT66DL can perform a wide range of tests: Continuity Insulation Hi Current Loop Lo Current Loop PSC PFC RCD Volts Earth Resistance SPD Phase Rotation PAT The full specifications of the Kewtech KT66DL 12-in-1 MFT are detailed below With a 3.5 inch colour LCD dot matrix display the Kewtech KT66DL boasts an advanced internal memory with help options explaining how to connect the instrument according to the selected function. Rated CAT IV 300V and CAT III 600V, the KT66DL is fully in line with the latest IEC safety guidelines. Kewtech KEWEVSE EV Charging Point Adapter The Kewtech KEWEVSE EV Charging Point Adapter is a highly portable device which when used in combination with a suitable Multifunction Tester such as the KT66DL, enables loop, RCD and Residual Direct Current Devices (RDCD) testing. It can simulate the presence of an electric vehicle in order to test the functionality of EV supply equipment, including detecting a PE fault. Capable of PP simulation & CP states A, B, C, D, this adapter uses bright LEDs to provide clear visual indication. Key Features 12-in-1 multifunction tester For testing EV charging points Capable of insulation & continuity testing High & low current testing with anti-trip technology Phase rotation and earth rotation features are included. RCD testing facility with EV charging point test Loop, RCD and RDCD testing Loop testing system includes 3 & 2-wire low current test options Includes PE Pre-Test PP simulation & CP states A, B, C, D CP Error / PE Error/ Earth fault LED indication of Phases Colour LCD display Intuitive design with a simple interface Advanced internal memory. Rated CAT IV 300V and CAT III 600V Kewtech part number: KT66EVKewtech KT Series Comparison Table   KT63DL KT63 Plus KT65DL KT66DL 200mA Continuity Test ✔ ✔ ✔ ✔ Automatic Test Lead Null ✔ ✔ ✔ ✔ 250, 500 & 1000V Insulation Resistance ✔ ✔ ✔ ✔ PAT Testing with optional PAT Adaptor 1 ✔ ✔ ✔ ✔ Continuous Live Warning ✔ ✔ ✔ ✔ High Voltage LED Light ✔ ✔ ✔ ✔ 3 Wire No-Trip Loop Test ✔ ✔ ✔ ✔ 2 Wire No-Trip Loop Test       ✔ High Current Loop Test ✔ ✔ ✔ ✔ PSC/PFC Test ✔ ✔ ✔ ✔ RCD Type AC & A: 10, 30, 100, 300 & 500 mA ✔ ✔ ✔ ✔ RCD Type ACS & A: 100 & 300 mA ✔ ✔ ✔ ✔ RCD Type AC: ACS, ACS & AS 10, 30, 100, 300, 500 & 1000 mA ✔ ✔ ✔ ✔ RCD Auto Test: 30 mA ✔ ✔ ✔ ✔ RCD Auto Test: 10, 30, 100, 300, 500 & 1000 mA     ✔ ✔ RCD Auto Test All Results On One Screen   ✔ ✔ ✔ 6mA DC RCD Test (for EVSE)       ✔ 'Hands Free' Testing ✔ ✔ ✔ ✔ Wiring & Lead Polarity Check ✔ ✔ ✔ ✔ Volts Measurement ✔ ✔ ✔ ✔ Backlight ✔ ✔ ✔ ✔ Soft Carry Case ✔ ✔ ✔ ✔ IP Rating 54 54 40 40 All Auto RCD Results On One Screen   ✔ ✔ ✔ Remote Test Probe Included   ✔ ✔ ✔ 0.001Ω Resolution High Current Loop Test   ✔ ✔ ✔ 55V Loop Test   ✔ ✔ ✔ Phase Rotation   ✔ ✔ ✔ Protective Lid On Instrument     ✔ ✔ Touch Pad for Earth Potential Limits (25V or 50V)     ✔ ✔ Lockout Test Button     ✔ ✔ Earth Resistance Test     ✔ ✔ PAT Test Firmware     ✔ ✔ Download Memory     ✔ ✔ Colour Screen       ✔ 50kA PFC Range using 25A Test Current       ✔ Continuity 15mA Test Current Option       ✔ 0.001Ω resolution high current loop test   ✔ ✔ ✔ (25A test current) Continuity 15mA Test Current Option       ✔ Continuity 15mA Test Current Option       ✔ Insulation 100V       ✔ Polarisation and Dielectric Absorbtion Index       ✔ Digital Insulation Resistance Bargraph       ✔ Specifications Kewtech KT66DL 12-in-1 Multifunction Tester Loop Impedance Range: 20.00/200.0/2000Ω (auto-ranging) Display range: 0.00 - 20.99Ω / 16.0 - 209.9Ω / 160 - 2099Ω Measuring range: 0 – 2000Ω Accuracy: ±2.0% rdg ±8 dgt Open-circuit voltage: 7 – 14V DC Test current: 200mA test: 200mA or more (2Ω or less) 15mA test: 15mA ±3mA (short-circuit) Enabled if pre-set NULL value is 9Ω or less Buzzer: Buzzer sounds when measured resistance is 2Ω or less Volts Range: 300.0/600V (Auto-ranging) Display Range: Voltage: 2.0 – 314.9V, 240 – 629V Frequency: 40.0 – 70.0Hz (displayed at 2V or higher) Measuring Range: Voltage: 2 – 600V Frequency: 45 – 65Hz Accuracy: Voltage: ±2% rdg ±4 dgt Frequency: ±0.5% rdg ±2 dgt Uc (RCD) Mains voltage range: 100-260V Range: 100V Display range: 0.0 - 104.9V Measuring range: 0 - 100V Accuracy: +5% to +15% rdg ±8 dgt 230V Test current: 50 % or less of I∆n Phase Rotation Measuring Range: 48 – 600V / 45 - 65Hz Criteria of Judgement: Correct sequence: Clockwise symbol and “1, 2, 3” are displayed Reversed sequence: Counter-clockwise symbol and “3, 2, 1” are displayed General Applicable Standards: IEC 61010-1 CATIII (600V) CATIV (300V) pollution degree 2, IEC 61010 -Tester, -2-030, -2-034, IEC61557-1,2,3,4,5,6,7,10, IEC 60529 IP40, EN 61326-2-2 (EMC) Dimensions: 136 (L) x 235(W) x 114 (D) mm Weight: 1300g including batteries (8 x AA / LR6) Earth   Precise Measurement Simplified Measurement Range 20.00 / 200.0 / 2000Ω (auto-ranging) Accuracy 20Ω range; ±2% rdg ±0.08ΩThe other ranges: ±2% rdg ±3 dgt(Aux. earth resistance: 100Ω) ±2% rdg ±0.08ΩThe other ranges: ±2% rdg ±3 dgt OutputCurrent 20Ω range: approx. 3mA, 200v range: approx. 1.7mA2000Ω range: approx. 0.7mA Frequency: 825Hz Insulation Rated Voltage 100V 250V 500V 1000V SPD (Varistor) 1000V) Range 2.000/20.00/200.0MΩ auto-ranging 20.00/200.0/1000MΩ auto-ranging 20.00/200.0/2000MΩ 0 -1000V (increases in 1V steps) Display Range 0.000 - 2.099MΩ,1.60 - 20.99MΩ,16.0 - 209.9MΩ 0.00 - 20.99MΩ,16.0 - 209.9MΩ,160 - 1049MΩ 0.00 - 20.99MΩ,16.0 - 209.9MΩ,160 - 2099MΩ 1049V Measuring Range 0 - 200MΩ 0 - 1000MΩ 0 - 2000MΩ 0 - 1049V Accuracy 2.000MΩ range: ±2% rdg ±6 dgt20.00MΩ range: ±2% rdg ±6 dgt200MΩ range: ±5% rdg ±6 dgt 20.00MΩ range: ±(2% rdg +6 dgt), 200.0MΩ range: ±(2% rdg +6 dgt) ±5% rdg +5 dgt 1000MΩ range: ±(5% rdg +6 dgt) 2000MΩ range: ±(5% rdg +6 dgt) Reated meas. current 1.0 - 1.2mA at 100kΩ 1.0 - 1.2mA at 250KΩ 1.0 - 1.2mA at 500kΩ 1.0 - 1.2mA at 1MΩ 1.0mA Loop Function Loop ATT Loop High 3-Wire L-PE 2-Wire L-PE L-PE0.01ΩRes L-PE0.001ΩRes L-N/L-L Mains inputVoltage Range 100 – 260V 50/60Hz (L-N < 20Ω) 48 – 260V 50/60Hz 100 - 260V 50/60Hz 48 - 260V 50/60Hz Range Loop 20.00/200.0/2000Ω (auto-ranging) 20.00/200.0/2000Ω 2.000Ω 20.00Ω PFC/PSC 2000A/20kA 2000A/20kA (PFC only) 2000A/50kA (PFC only) 2000A/20kA (PSC only) 2000A/20kA (PSC only) Display range Loop 0.00 – 20.99Ω21.0 – 209.9Ω210 – 2099Ω 0.00 – 20.99Ω21.0 – 209.9Ω210 – 2099Ω 0.00 – 20.99Ω21.0 – 209.9Ω210 – 2099Ω 0.000 – 2.099Ω 0.00 – 20.99Ω PFC/PSC 0 - 2099A2.10 - 20.99kA 0 - 2099A2.10 - 20.99kA(PFC only) 0 - 2099A2.10 - 50.49kA(PFC only) 0 - 2099A2.10 - 20.99kA(PFC only) 0 - 2099A2.10 - 20.99kA(PSC only) Meas. range Loop 0 – 2000Ω 0 – 2000Ω 0 – 2000Ω 0 – 2Ω 0 – 20Ω Accuracy Loop ±(3% rdg +6 dgt) ±(3% rdg +10 dgt) ±(3% rdg +6 4gt) ±(3% rdg +25mΩ) ±(3% rdg +4 dgt) PFC/PSC Depending on the accuracies of voltage and LOOP measurements Test current @ 230V L-N:6A/60msN-PE:10mA (5.3Hz) L-PE: 15mA 20Ω: 6A/20ms,200Ω: 0.5A/20ms2000Ω: 15mA/500ms 25A/20ms 6A/20ms RCD (Mains input voltage range: 100V – 260V 50/ 60Hz. For Type AC and A RCDs rated at 100mA or higher: 190 – 260V) Mode Rated residual operating current (mA)(I∆n) Test current Duration Current (mA) rms Accuracy @230V Meas. time Accuracy x 1/2 AC G: 10/30/100/300/500/1000 S: 100/300/500 I∆n×1/2 -8% to-2% VAR:-10% to 0% 2000ms Trip Time ±(1%+2ms) A/F G: 10/30/100/300/500 AS:100/300/500 I∆n×0.35 -10% to 0% B G: 10/30/100/300 S:100/300 I∆n×1/2 -10% to 0% x 1 AC G: 10/30/100/300/500/1000 S: 100/300/500 I∆n +2% to +8% VAR:0% to +10% G:550ms S:1000ms Measuring time ±3% of FS A/F G: 10/30/100/300/500 AS:100/300/500 I∆n×1.4 (10mA: I∆n×2) 0% to +10% B G: 10/30/100/300 S:100/300 I∆n×2 0% to +10% 6 mA DC I∆n 0% to +10% 10.5s   x 5 AC G: 10/30/100 S: 100 I∆n×5 +2% to +8% VAR:0% to +10% 410ms   A/F G: 10/30/100 AS: 100 I∆n×5×1.4 0% to +10% B 10/30 I∆n×2×5 0% to +10% Ramp 20 to 110% AC 10/30/100/300/500 S: 100/300/500 I∆n -4% to +4% by 10%G: 300ms S: 500ms Measuring time ±3% of FS A/F G: 10/30/100/300/500 AS:100/300/500 I∆n×1.4 (10mA:I∆n×2) -10% to +10% B G: 10/30/100/300 S: 100/300 I∆n×2 -10% to +10% by 2% /150ms Ramp EV 30 to 100% 6 mA DC I∆n -10% to +10% by 2% / 500ms  

All reviews


Rated 5 out of 5 stars

Amazing bit of kit

Quality: 5
Value for money: 5